Temperature Control Measures

Aligned with FSSC 22000 – ISO 22000:2018 & ISO/TS 22002-1/5 Requirements

Requirement Overview

FSSC 22000-certified organizations are required to maintain proper storage and transport conditions for temperature-sensitive products to prevent contamination, spoilage, and quality degradation. According to ISO 22000:2018 Clause 8.5.4 and ISO/TS 22002-1/5, temperature control must be based on product-specific requirements and risk analysis and must be monitored and verified.

Failure to control temperatures may lead to microbiological growth, loss of product integrity, regulatory non-compliance, and failure to meet customer expectations.

Key Compliance Objectives

  • ✓ Identify and apply temperature control measures based on hazard and risk analysis

    ✓ Use validated, calibrated monitoring equipment

    ✓ Maintain complete records of temperature monitoring and corrective actions

    ✓ Ensure product safety across all stages: receiving, storage, handling, and dispatch

Step-by-Step Compliance Implementation

1. Define Temperature Requirements by Product Type

  • Key Actions Include:

    • • Identify all products requiring environmental control

      • Establish critical limits for temperature ranges (e.g., frozen ≤ –18°C, chilled 0–5°C)

      • Base limits on hazard analysis, product characteristics, and regulatory guidelines

    Evidence to Maintain:

    • • Product temperature specification sheets

      • Regulatory references (e.g., Codex, FDA, EU)

      • HACCP or risk assessment documentation

2. Equip and Calibrate Monitoring Devices

  • Monitoring Options:

    • • Continuous monitoring systems (e.g., data loggers, IoT sensors)

      • Manual checks using traceable calibrated thermometers

      • Alerts or alarms for excursions

    Evidence to Maintain:

    • • Calibration certificates and schedules

      • Maintenance and validation logs

      • Mapping studies for cold rooms or transport units

3. Monitor and Record Temperatures

  • Monitoring Frequencies:

    • • Based on risk and product sensitivity (e.g., continuous or scheduled checks)

      • Include all temperature-controlled steps: receiving, storage, transport

      • Immediate action required on deviations

    Evidence to Maintain:

    • • Electronic or manual temperature records

      • Receiving inspection logs

      • Alerts and incident response documentation

4. Respond to Temperature Deviations

  • Response Protocols Include:

    • • Quarantine affected batches

      • Conduct root cause analysis (RCA)

      • Implement corrective and preventive actions (CAPA)

      • Notify relevant parties for disposition

    Evidence to Maintain:

    • • Nonconformance and deviation logs

      • Disposition and investigation reports

      • CAPA documentation linked to deviation events

5. Conduct Internal Reviews and Verification

  • Ongoing Verification Activities:

    • • Review temperature logs monthly or as defined in FSMS

      • Conduct internal audits on cold chain and monitoring process

      • Include temperature control in management review

    Evidence to Maintain:

    • • Internal audit checklists and reports

      • Verification records

      • Review meeting minutes

Common Audit Findings & Recommended Fixes

Audit Finding Recommended Action
No documented temperature specifications Create product-specific control limit sheets based on hazard analysis
Incomplete or missing temperature logs Standardize and digitize monitoring forms
Uncalibrated or expired equipment Establish and follow calibration program
No corrective actions for temperature excursions Require RCA and CAPA; include review in FSMS

Auditor Verification Checklist

During an FSSC 22000 audit, be prepared to present:

  • • HACCP or hazard analysis identifying temperature control needs

    • Temperature requirement documentation per product category

    • Monitoring equipment calibration records

    • Temperature monitoring logs (receiving, storage, transport)

    • Evidence of deviation handling and CAPA

    • SOPs for temperature control and deviation response

    • Internal audit and verification reports

Implementation Roadmap

Build Your Program

  • ✓ Identify temperature-sensitive products

    ✓ Document critical limits and reference sources

Train and Equip

  • ✓ Calibrate and validate monitoring tools

    ✓ Train receiving, storage, dispatch, and QA teams

Monitor and Respond

  • ✓ Maintain complete records

    ✓ Investigate all deviations

Review and Improve

  • ✓ Schedule periodic internal reviews

    ✓ Update procedures based on findings and technology changes

Why This Matters?

  • ✓ Ensures compliance with FSSC 22000, ISO 22000:2018, and PRP standards

    ✓ Reduces risk of spoilage, recalls, and non-conformance

    ✓ Supports continuous improvement and traceability

    ✓ Demonstrates due diligence and audit readiness

Support Tools Available

Food Safety Systems provides:

  • ✓ Temperature control SOP templates

    ✓ Deviation response and CAPA forms

    ✓ Calibration tracking tools

    ✓ Internal audit and verification templates